Contact Us

Products

Product Category

Subtitle introduction,It can be replaced later, and is currently only for display purposes

Product Categories

Need Assistance?
Our technical experts are ready to help you find the right solution.

Contact Technical Support
SML-HP Submersible Level Transmitter

SML-S324 Anti-clogging submersible level transmitter for sewage


This series of anti‑sediment & anti‑silt submersible level transmitters is optimized for sewage, sludge and silt working conditions. Measuring range covers 0‑3 ~ 0‑100 mH₂O. It supports 2‑wire 4‑20 mA, 3‑wire voltage outputs and digital interfaces HART, RS485, I2C.


Compliant with IEC61000‑4‑5 Level‑4 lightning‑proof standard, the transmitter provides outstanding surge and EMI anti‑interference capability. Accuracy grades 1%FS / 0.5%FS /0.25%FS /0.1%FS are optional subject to measuring range. Operating temperature spans ‑20℃~85℃ (extended‑40℃~125℃ optional). It passes IEC 60068‑2‑6 vibration and IEC 60068‑2‑27 mechanical‑shock tests.


Housing material includes 304SS, 316L, TC4; wetted diaphragm is Al₂O₃ ceramic. Cable options: PUR, PE, PTFE, PVC. Designed for long‑term submerged deployment in sewage tanks, sediment pools and silt‑rich water environment.


  • Description
  • Specifications
  • Applications

Specification


ItemSpecification
Measuring Range0‑3, 0‑5, 0‑10, 0‑20, 0‑50, 0‑100 mH₂O
Overload Pressure1.5×FS
Output Signal2‑wire:4‑20mA3‑wire:0‑10V,0‑5V,1‑5V,0.5‑4.5V(ratiometric)Digital:4‑20mA+HART,4‑20mA+RS485,RS485,I2C
Power Supply4‑20mA:DC8‑30VVoltage:DC8‑30V /14‑30VRatiometric 0.5‑4.5V:5V±10%I2C:DC3‑5VHART:DC12‑30V
AccuracyRange≥1mH₂O:std 1%FS, opt 0.5%FSRange≥3mH₂O:std 0.5%FS,opt 0.25%FSRange≥10mH₂O:std 0.5%FS,opt 0.25%FS,0.1%FSComplies with JJG860, JJG882
Operating Temperature‑20℃~85℃(opt‑40℃~125℃)
Compensation Temp≤10mH₂O:0~50℃;>10mH₂O:0~70℃(opt‑10~80℃)
Storage Temperature‑40℃ ~125℃
Temperature DriftStd:±0.03~0.05%FS/℃;Opt:±0.02%FS/℃
Long‑term Stability≤0.2%FS/year (@0.5%FS)
Response TimeBoot‑up:100ms(opt10ms); Response:10ms(opt1ms)
Vibration Resistance10g, IEC 60068‑2‑6
Shock Resistance500g, IEC 60068‑2‑27
Service Life10 million pressure cycles
Diaphragm MaterialAl₂O₃ Ceramic
Housing MaterialStd:304SS; Opt:316L, TC4
Cable MaterialStd:PUR; Opt:PE,PTFE,PVC
ProtectionIEC61000‑4‑5 Level‑4 lightning & surge protection


Ordering Guide

CodeDescription
Series323:Sediment type;325:Sewage special;327:Silt flange type
OutputS1:4‑20mA;S2:0.5‑4.5V;S3:0‑5V;S4:0‑10V;S5:I2C;S6:RS485
Power supplyU1:8‑30VDC;U2:5VDC;U3:3.3VDC
Housing material30‑304SS;31‑316L;32‑TC4;33‑PTFE;34‑PVDF
MountingC0:Put‑in submersible type


Applications


  • Water works & water plant

  • Sewage treatment system, sewage tanks and sedimentation pools

  • Deep wells, dams and reservoirs

  • Flood‑control and irrigation monitoring

  • Liquid‑level measurement for media containing sediment, sludge and silt


Short list for web sidebar:Water plant, sewage treatment, deep well, dam, flood‑control, irrigation, sediment & silt‑containing liquid monitoring


Related Products